135,000৳ Original price was: 135,000৳ .120,000৳ Current price is: 120,000৳ .





The Solis 5kW Hybrid Single Phase Inverter is a high-efficiency, smart energy-management solution designed for modern homes and small businesses. Built with advanced hybrid technology, it allows seamless integration of solar panels, grid power, and battery storage—ensuring you enjoy uninterrupted electricity even during load-shedding or grid failure.
Solis 5kW Hybrid Single Phase Inverter Engineered with Solis’s trusted reliability, this 5kW hybrid inverter delivers maximum solar harvesting with industry-leading MPPT efficiency and intelligent battery charging. Whether you’re reducing electricity bills, improving energy independence, or powering essential home appliances, the Solis 5kW Hybrid Inverter ensures stable, clean, and optimized power delivery.
Solis 5kW Hybrid Single Phase Inverter, Its compact design, user-friendly monitoring, and durable construction make it one of the best choices for residential solar systems in Bangladesh. With smart app control, advanced safety protection, and high conversion efficiency, the inverter provides long-term performance with low maintenance and fast ROI.
| Models | 3K | 3.6K | 5K | 6K | 8K | 10K |
| Input DC (PV side) | ||||||
| Recommended max. PV array size | 6 kW | 7.2 kW | 10 kW | 12 kW | 16 kW | 20 kW |
| Max. usable PV input power | 4.8 kW | 5.76 kW | 8 kW | 9.6 kW | 12.8 kW | 16 kW |
| Max. input voltage | 500 V | |||||
| Rated voltage | 330 V | |||||
| Start-up voltage | 90 V | |||||
| MPPT voltage range | 90 – 435 V | |||||
| Max. input current | 16 A / 16 A | 32 A / 32 A | 42 A / 42 A | |||
| Max. short circuit current | 20 A / 20 A | 40 A / 40 A | 48 A / 48 A | |||
| MPPT number / Max. input strings number | 2 / 2 | 2 / 4 | ||||
| Battery | ||||||
| Battery type | Li-ion / Lead-acid | |||||
| Battery voltage range | 40 – 60 V | |||||
| Max. charge / discharge power | 3 kW | 3.6 kW | 5 kW | 6 kW | 8 kW | 10 kW |
| Max. charge / discharge current | 70 A | 80 A | 112 A | 135 A | 190 A | 208 A |
| Communication | CAN / RS485 | |||||
| Output AC (Grid side) | ||||||
| Rated output power | 3 kW | 3.6 kW | 5 kW | 6 kW | 8 kW | 10 kW |
| Max. apparent output power | 3 kVA | 3.6 kVA | 5 kVA | 6 kVA | 8 kVA | 10 kVA |
| Operation phase | L/N/PE | |||||
| Rated grid voltage | 220 V / 230 V | |||||
| Rated grid frequency | 50 Hz / 60 Hz | |||||
| Rated grid output current | 13.7 A / 13.1 A | 16.4 A / 15.7 A | 22.8 A / 21.8 A | 27.3 A / 26.1 A | 36.4 A / 34.8 A | 45.5 A / 43.5 A |
| Max. output current | 13.7 A / 13.1 A | 16.4 A / 15.7 A | 22.8 A / 21.8 A | 27.3 A / 26.1 A | 36.4 A / 34.8 A | 45.5 A / 43.5 A |
| Power factor | > 0.99 (0.8 leading – 0.8 lagging) | |||||
| THDi | < 3% | |||||
| Input AC (Grid side) | ||||||
| Input voltage range | 187 – 253 V | |||||
| Max. input current | 21 A | 25 A | 32 A | 40 A | 50 A | 65 A |
| Frequency range | 45 – 55 Hz / 55 – 65 Hz | |||||
| Output AC (Back-up) | ||||||
| Rated output power | 3 kW | 3.6 kW | 5 kW | 6 kW | 8 kW | 10 kW |
| Max. apparent output power | 2 times of rated power, 10 s | |||||
| Back-up switch time | < 10 ms | |||||
| Rated output voltage | L/N/PE, 220 V / 230 V | |||||
| Rated frequency | 50 Hz / 60 Hz | |||||
| Rated output current | 13.7 A / 13.1 A | 16.4 A / 15.7 A | 22.8 A / 21.8 A | 27.3 A / 26.1 A | 36.4 A / 34.8 A | 45.5 A / 43.5 A |
| Max. AC passthrough current | 35 A | 35 A | 40 A | 40 A | 50 A | 65 A |
| THDv (@linear load) | < 2% | |||||
| Input Generator | ||||||
| Max. input power | 3 kW | 3.6 kW | 5 kW | 6 kW | 8 kW | 10 kW |
| Max. input current | 13.7 A / 13.1 A | 16.4 A / 15.7 A | 22.8 A / 21.8 A | 27.3 A / 26.1 A | 36.4 A / 34.8 A | 45.5 A / 43.5 A |
| Rated input frequency | 50 Hz / 60 Hz | |||||
| Efficiency | ||||||
| Max. efficiency | 96.2% | |||||
| EU efficiency | 96.1% | |||||
| BAT charged by PV / AC max. efficiency | 95.3% / 93.9% | |||||
| BAT discharged to AC max. efficiency | 93.8% | |||||
| Protection | ||||||
| Ground fault monitoring | Yes | |||||
| DC reverse-polarity protection | Yes | |||||
| Integrated AFCI 2.0 | Optional | |||||
| Protection class / Over voltage category | I / II (PV and BAT), III (MAINS and BACKUP and GEN) | |||||
| General Data | ||||||
| Dimensions (W × H × D) | 335 × 560 × 253 mm | |||||
| Weight | 23 kg | 23.5 kg | 24 kg | |||
| Topology | High frequency isolation (for battery) | |||||
| Operating ambient temperature range | -40 ~ +60°C | |||||
| Ingress protection | IP66 | |||||
| Noise emission (typical) | < 65 dB(A) | |||||
| Cooling concept | Natural cooling | Intelligent fan-cooling | ||||
| Max. operation altitude | 3000 m | |||||
| Grid connection standard | NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA, NBR 16149, NBR 16150, G98, CEI 0-21 | |||||
| Safety / EMC standard | IEC/EN 62109-1/-2, EN 61000-6-2/-3 | |||||
| Features | ||||||
| DC connection | MC4 plug (PV port) / Terminal Block (BAT port) | |||||
| AC connection | Terminal Block | |||||
| Display | 7.0″ LCD display & Bluetooth + APP | |||||
| Communication | RS485, CAN, Optional: Wi-Fi, GPRS, LAN | |||||