| System rating (Name Plate) | VA | 900/ 750w | |||||||
| Input current at no load at Nominal Battery voltage | Adc | 2.6 | |||||||
| Full Load Input Current ±2A | Amp | 60 | |||||||
| Operating DC voltage | V | 12 | |||||||
| Nominal Output voltage in inverter mode | Vac | 220V ± 7V | |||||||
| Nominal Output Frequency of Inverter | Hz | 50 ± 1 HZ | |||||||
| Output voltage regulation | % | 180-220 | |||||||
| Overload capacity | Sec | 6 Retry | |||||||
| Cooling Fan ON at temp | OC | 60 (or >50% of Rated Load or >8A) | |||||||
| Cooling Fan Off at temp | OC | 55 (or <40% of Rated Load or <5A Charging) | |||||||
| Battery low voltage alarm per battery | Vdc | 10.8 /10.5± 0.2 (11.5-default for LiFePo4 batt) | |||||||
| Battery low voltage cut per battery | Vdc | 10.5 /10.2± 0.2 (With 4 Retry) (11.0-default for LiFePo4 batt) | |||||||
| Max Battery charging voltage by grid per battery | Vdc | 14.4 ± 0.2 | |||||||
| satiable for Tub-14.4V/28.8V,FALT-14.2V/28.4V,SMF-14.2V/28.4,GEL-14.2V/28.4V, LiFePo4-14.0V/28.0V | |||||||||
| satiable for Tub-13.8V/27.6V,FLAT-13.6V/27.2V,SMF-13.8V/27.6,GEL-13.8V/27.6V, LiFePo4-Maintain Boost With Trickle Charging | |||||||||
| Max Battery charging current by grid in Hi/Lo option | Adc | 16/12 ±2A | |||||||
| satiable for Tub-12/16A,FLAT-10/14A, SMF-10/14A,Gel-10/16A, LiFePo4-12/16 | |||||||||
| Grid low cut voltage (IT load/Normal load) | Vac | 180/100 ± 10 | |||||||
| Grid low cut voltage recovery (IT load/Normal load) | Vac | 190/100 ± 10 | |||||||
| Grid high cut voltage (IT load/Normal load) | Vac | 265/280 ± 10 | |||||||
| Grid high cut voltage recovery (IT load/Normal load) | Vac | 255/270 ± 10 | |||||||
| Grid charging Enable/Disable | Yes | ||||||||
| Selection of UPS Load/Normal Load | Yes | ||||||||
| Protections | Overload, Battery Deep discharge, Battery Overcharge, Short circuit(1retry),Battery Hi, Over Temp, Fuse/MCB Trip, battery reverse | ||||||||
| LCD Display parameters | Product, UPS ON/OFF, Mains Status, Mains voltage, Mains Frequency. Output Voltage, output frequency, Battery Voltage, Load percentage, Charging Status, Charging Mode ,Battery Mode, UPS Mode ON/OFF,Grid Charge ON/Off,Inv Type, over load, short circuit, battery low, over temp, Fuse/MCB trip, Battery high | ||||||||
| Changeover time from inverter to mains in UPS mode | ms | <10 | |||||||
| Changeover time from inverter to mains in Normal mode | ms | <10 | |||||||
| Changeover time from mains to inverter in UPS mode | ms | <10 | |||||||
| Changeover time from mains to inverter in Normal mode | ms | <40 | |||||||
| Fuse in battery path | Internal Fuse | ||||||||
| Input Protection | Resettable Circuit breaker | ||||||||