Long Ran LENTO 1050 12V DC Product 900va

Original price was: 12,500৳ .Current price is: 11,990৳ .Save 510৳ 
  • Highly efficient battery charging
  • stable and 100% pure sine wave output
  •  Indications for Mains ON, UPS ON
  • Thermal Trip on LCD Display
  • Nominal Output voltage in inverter mode 220v
  • Genuine productsWith manufacturer warranty
  • Fast deliveryFast nationwide delivery
  • Technical supportGuidance for installers and customers

Product details

 

System rating (Name Plate) VA 900/ 750w
Input current at no load at Nominal Battery voltage Adc 2.6
Full Load Input Current ±2A Amp 60
Operating DC voltage V 12
Nominal Output voltage in inverter mode Vac 220V ± 7V
Nominal Output Frequency of Inverter Hz 50 ± 1 HZ
Output voltage regulation % 180-220
Overload capacity Sec 6 Retry
Cooling Fan ON at temp OC 60 (or >50% of Rated Load or >8A)
Cooling Fan Off at temp OC 55 (or <40% of Rated Load or <5A Charging)
Battery low voltage alarm per battery Vdc 10.8 /10.5± 0.2 (11.5-default for LiFePo4 batt)
Battery low voltage cut per battery Vdc 10.5 /10.2± 0.2 (With 4 Retry) (11.0-default for LiFePo4 batt)
Max Battery charging voltage by grid per battery Vdc 14.4 ± 0.2
satiable for Tub-14.4V/28.8V,FALT-14.2V/28.4V,SMF-14.2V/28.4,GEL-14.2V/28.4V, LiFePo4-14.0V/28.0V
satiable for Tub-13.8V/27.6V,FLAT-13.6V/27.2V,SMF-13.8V/27.6,GEL-13.8V/27.6V, LiFePo4-Maintain Boost With Trickle Charging
Max Battery charging current by grid in Hi/Lo option Adc 16/12 ±2A
satiable for Tub-12/16A,FLAT-10/14A, SMF-10/14A,Gel-10/16A, LiFePo4-12/16
Grid low cut voltage (IT load/Normal load) Vac 180/100 ± 10
Grid low cut voltage recovery (IT load/Normal load) Vac 190/100 ± 10
Grid high cut voltage (IT load/Normal load) Vac 265/280 ± 10
Grid high cut voltage recovery (IT load/Normal load) Vac 255/270 ± 10
Grid charging Enable/Disable Yes
Selection of UPS Load/Normal Load Yes
Protections Overload, Battery Deep discharge, Battery Overcharge, Short circuit(1retry),Battery Hi, Over Temp, Fuse/MCB Trip, battery reverse
LCD Display parameters Product, UPS ON/OFF, Mains Status, Mains voltage, Mains Frequency. Output Voltage, output frequency, Battery Voltage, Load   percentage,   Charging   Status,   Charging   Mode   ,Battery   Mode,   UPS Mode ON/OFF,Grid Charge ON/Off,Inv Type, over load, short circuit, battery low, over temp, Fuse/MCB trip, Battery high
More Specifications
Changeover time from inverter to mains in UPS mode ms <10
Changeover time from inverter to mains in Normal mode ms <10
Changeover time from mains to inverter in UPS mode ms <10
Changeover time from mains to inverter in Normal mode ms <40
Fuse in battery path Internal Fuse
Input Protection Resettable Circuit breaker