| Models | 3K | 3.6K | 5K | 6K |
| Input DC (PV side) | ||||
| Recommended max. PV array size | 6 kW | 7.2 kW | 10 kW | 12 kW |
| Max. usable PV input power | 4.8 kW | 5.76 kW | 8 kW | 9.6 kW |
| Max. input voltage | 600 V | |||
| Rated voltage | 330 V | |||
| Start-up voltage | 90 V | |||
| MPPT voltage range | 90 – 520 V | |||
| Max. input current | 16 A / 16 A | |||
| Max. short circuit current | 24 A / 24 A | |||
| MPPT number / Max. input strings number | 2 / 2 | |||
| Battery | ||||
| Battery type | Li-ion / Lead-acid | |||
| Battery voltage range | 40 – 60 V | |||
| Max. charge / discharge power | 3 kW | 3.6 kW | 5 kW | 6 kW |
| Max. charge / discharge current | 70 A | 80 A | 112 A | 135 A |
| Communication | CAN / RS485 | |||
| Output AC (Grid side) | ||||
| Rated output power | 3 kW | 3.6 kW | 5 kW | 6 kW |
| Max. apparent output power | 3.3 kVA | 4 kVA | 5.5 kVA | 6.6 kVA |
| Operation phase | 1/N/PE | |||
| Rated grid voltage | 220 V / 230 V | |||
| Rated grid frequency | 50 Hz / 60 Hz | |||
| Rated grid output current | 13.6 A / 13.0 A | 16.4 A / 15.7 A | 22.7 A / 21.7 A | 27.3 A / 26.1 A |
| Max. output current | 15 A | 20 A | 25 A | 30 A |
| Power factor | > 0.99 (0.8 leading – 0.8 lagging) | |||
| THDi | < 2% | |||
| Input AC (Grid side) | ||||
| Input voltage range | 187 – 253 V | |||
| Max. input current | 20 A | 25 A | 32 A | 40 A |
| Frequency range | 45 – 55 Hz / 55 – 65 Hz | |||
| Output AC (Back-up) | ||||
| Rated output power | 3 kW | 3.6 kW | 5 kW | 6 kW |
| Max. apparent output power | 2 times of rated power, 10 s | |||
| Back-up switch time | < 4 ms | |||
| Rated output voltage | 1/N/PE, 220 V / 230 V | |||
| Rated frequency | 50 Hz / 60 Hz | |||
| Rated output current | 13.6 A / 13.0 A | 16.4 A / 15.7 A | 22.7 A / 21.7 A | 27.3 A / 26.1 A |
| Max. output current | 15 A | 20 A | 25 A | 30 A |
| Max. AC passthrough current | 35 A | 40 A | ||
| THDv (@linear load) | < 2% | |||
| Efficiency | ||||
| Max. efficiency | > 96.9% | |||
| EU efficiency | > 96.5% | |||
| Protection | ||||
| DC reverse-polarity protection | Yes | |||
| Ground fault monitoring | Yes | |||
| Integrated AFCI | Yes (1) | |||
| Protection class / Over voltage category | I / II (PV and BAT), III (MAINS and BACKUP and GEN) | |||
| General Data | ||||
| Dimensions (W × H × D) | 406 × 560 × 205 mm | |||
| Weight | 24 kg | |||
| Topology | High frequency isolation (for battery) | |||
| Operating ambient temperature range | -40 ~ +60°C | |||
| Ingress protection | IP66 | |||
| Cooling concept | Natural cooling | |||
| Max. operation altitude | 4000 m | |||
| Grid connection standard | NRS 097-2-1, IEC 62116, IEC 61727, IEC 60068, IEC 61683, EN 50530, MEA, PEA | |||
| Safety / EMC standard | IEC/EN 62109-1/-2, EN 61000-6-2/-3 | |||
| Features | ||||
| DC connection | MC4 plug (PV port) / Terminal Block (BAT port) | |||
| AC connection | Terminal Block | |||
| Display | LED indicator & Bluetooth + APP | |||
| Communication | RS485, CAN, Optional: Wi-Fi, GPRS, LAN | |||